**The pump** has a constant pumping rate between certain depths. The pump begins operating from empty when the depth within it exceeds the first depth. If the depth then exceeds a second value, a second flow rate will apply until the depth drops below that value. The pump then continues to operate at the first flow rate until the depth drops below a stopping level.

![image](media://0ba00e1a-650f-46d8-9fc0-e4be99cd01b4)

***Depth for Q1. ***Depth at which the first pumping rate begins, ft [m].

***Depth for Q2. ***Depth at which the second pumping rate begins, ft [m].

***Pump Rate 1 (Q1). ***Pumping rate when the water depth within the pump exceeds the first depth, but is less than the second depth, in cfs [cms]. This rate applies while the depth is below the second depth and the pump is still operating.

***Pump Rate 2 (Q2). ***Pumping rate when the water depth within the pump exceeds the second depth, in cfs [cms]. This rate applies only while the depth exceeds the second depth.

***Stop Pumping Depth. ***The depth below which all pumping stops, ft [m].

***Average Cross-Section Area. ***The average cross-sectional area of the pump well used to determine the pump well volume, ft^2 [m^2].

***Gauged Data***.Measured time series data can be entered directly at a node or link for comparison with model results. Visit the [Gauged Data](https://help-innovyze.atlassian.net/wiki/spaces/xps/pages/19662589/Node+Data#NodeData-GaugedData) section for details on this parameter.