title: "Manning Formula"
canonical: "https://help.innovyze.com/space/infodrainage2021v1/16547960/Manning%20Formula"
format: markdown
---
The Manning Formula is used for Velocity calculations within the software.

![image](media://3e08ac0c-5f4a-4e7f-a16f-e51e5d2f8b6b)

where;

V =Velocity

n = Manning's roughness coefficient (see Pipe Roughness)

R = Hydraulic Radius

S = Hydraulic gradient


The equation is in metre-per-second units but the n values are the same as those specified in the foot-per-second format of the equation (e.g. smooth concrete pipe n = 0.012 approximately).  The formula is sometimes known as Strickler's formula and 1/n as the Strickler's coefficient.

A concrete pipe with a smooth interior would have a Manning's n of approximately 0.012.  

Manning's n may be derived from 1/Strickler coefficient.