Allows threshold flow rates for the upper and lower limits of the bypass, anything outside of these limits is seen as bypassing this inlet. This leaves anything between these values entering the Stormwater Control or Junction.


Example:

Low Bypass Rate = 2 l/s

High Bypass Rate = 10 l/s

With an approach flow of 15 l/s the captured flow will be 8 l/s, with the 2l/s below and 5 l/s above bypassing the system

Workflow - What's next...?

Inflows connect to either  Junctions or  Stormwater controls  via  Inlets . Specify an  Low/High Flow on these objects then choose to connect to another Junction or Stormwater Control.