The amount of time that it will take for water landing on the roof area to enter the system. The inflows from the area will then  be evenly spread over this time when the area is analysed.

This amount of time can be calculated with the Time Of Concentration Calculator.
 

Analysis

The analysis is the same as the Time Area Diagram method with the time area diagram being built with an even spread of the area over the time of concentration. 

Eg. Time of Concentration = 3 mins, Area = 0.75ha

If the timestep is 1 minute, A1 = 0.25, A2 = 0.25, A3 = 0.25.


The rainfall profile and the time area diagram are combined with the volumetric runoff coefficient in the following way:


Q1 = (I1 x A1) x 2.78 x Cv

Q2 = (I1 x A2 + I2 x A1) x 2.78 x Cv

Q3 = (I1 x A3 + I2 x A2 + I3 x A1) x 2.78 x Cv


And so on… 


 

Scroll pdf ignore

Quick Link
imagecheckbox_checked.png
linkxpdrainage+Help+Documentation
titleBack to: Help Documentation


Section Pages

Children Display
depth2
pageRunoff Generation



Workflow - What's next...?

Connections  Inflows to your  Time of Concentration, specify  Inlets or  Outlets Outlets Outlets or connect to another Stormwater Control or  JunctionsInflows connect to either Junctions or Stormwater controls via Inlets. Specify an Outlet on these objects then choose to connect to another Junction or Stormwater Control.