Note

Group Editing for certain specific features may also be done by choosing the Group Editing icon or the Edit Domain icon under the InfoWater Pro Ribbon in the Edit Group . Refer to the sections on Group Editing and Edit Domain to learn more.

Delete a Junction?

To delete a junction, select the Delete Node

...

option Image Added in the InfoWater Pro Ribbon in the Edit Group → Edit Command dropbox. Select the node to be deleted and InfoWater prompts the user to confirm deletion (if the Delete Confirmation

...

checkbox Image Added is checked in the Operation Settings tab in the Preferences settingsImage Added.

The active selected junction in the Model Explorer - Attribute Tab window may also be deleted by selecting the Delete icon Image Added with the InfoWater prompt to confirm element deletion.

Note

All pipes attached to the Junction being deleted will also be deleted if the Auto Pipe Delete checkbox Image Added is checked in the Operation Settings tab in the Preferences settingsImage Added.  The Junction and associated pipes are deleted and saved in the InfoWater recycle bin and can be recalled from the database using the Model Explorer - Command Center Tab under Utilities -> Recall (node or Pipe) command. However, if Auto Database Packing Image Added is checked (Operation Settings tab in the Preferences settingsImage Added), then any element deleted is permanently deleted from the database and cannot be recalled. Deleted elements can be recalled until the Pack and then Clean commands (found in the Model Explorer - Command Center Tab under Utilities → Database menu list)are completed which removes deleted element ID's from the database.

Recall a deleted Junction?

To recall a deleted junction, go to Model Explorer - Command Center Tab under Utilities -> Recall and select theNode command. In order to perform the recall, the user must know the ID of the junction that was deleted. You may choose the Show Deleted Node command to obtain a list of  nodes deleted from the InfoWater project but saved in the InfoWater recycle bin. Deleted elements can be recalled until the Pack and then Clean commands (found in the Model Explorer - Command Center Tab under Utilities → Database menu list) are completed which removes deleted element ID's from the database permanently.