Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Junction nodes are points placed at the intersection of two or more pipes (intersections or tees). Junctions are used to represent points of water consumption or inflow, points where specific analysis values (e.g., pressure, concentration) are desired, and at points where pipe attributes (e.g., diameter, material) change.  Junction Junction nodes must have their elevation above datum (e.g., sea level) specified in order for pressure computations to be meaningful.

How do I...

Create a Junction?

To create a junction node, do the following:

Click on the InfoWater Pro Ribbon in the Edit Group using the → Insert Command dropbox Image Modified.  

Select the Insert Junction icon from the → Insert Command dropbox  Image Modified.

Note

When the Insert Junction command is the active command it will be highlighted in Blue as shown: Image RemovedImage Added.

Once the command is initiated, select the location of the new node by

...

clicking anywhere on the map display. Suggest a new ID and/or a description on the Junction Identification dialog box and click

...

OK

...

 to accept the ID and create the junction. The junction should visually appear at the specified location. If the insert location is near an existing model pipe, the software will

...

prompt you

...

to insert the junction into that pipe. If you wish to split the pipe, the Junction Identification dialog box for the new junction and the new pipe will appear in a pop-up window.

Note

You can also use the Digitize Network iconfrom the → Insert Command dropbox  to create a pipe and node network " on the fly".  Once digitized, the user is you are able to add relevant modeling data in the Model Explorer - Attribute Tab window or via the DB Editor.

 Edit a Junction? 

Graphic Selection - To select a junction node for data edit do one of the following:

Choose the Select icon from the Model Explorer - Attribute Tab window and click on the specific Junction or select the InfoWater Pro Ribbon in the Edit Group using the → Select icon .

If a Junction has been prior selected and is a part of the Browse history, it can be re-selected by choosing it from the Browse-History section of the Model Explorer - Attribute Tab window.


Data Edit - To edit the data related to a junction, first select the junction using the tools above. Once selected, edit Junction related data by adding/modifying the fields in the Model Explorer - Attribute Tab window.  Additionally modifications may be done by editing the DB Tables that may be accessed from the InfoWater Pro Ribbon in the Edit Group using the → DB Editor icon Image Modified .

Graphic Edit  - To edit the node graphically do one of the following: From the  InfoWater Pro Ribbon in the Edit Group using the → Edit Command dropbox icon Image Modified select the Move Node command 

...

Image Added from the

...

drop-down menu list. Click on the mouse and hold the left click down on the junction to select it. With the junction is highlighted, move the node to the desired position

...

and left mouse click

...

. Once in the desired location, release the left mouse button and the node location will be updated to the new location.

Note

When the Move Node command in the InfoWater Pro Ribbon in the Edit Group → Edit Command dropbox is the active command it will be highlighted in Blue as shown: .

Note

If the user has you have not enabled "the Auto Length Calculation" checkbox under from the InfoWater Pro Ribbon in the Project Group using the Preferences icon and the Operations tab, all pipes connected to a node moved will not have their lengths automatically changed.

Edit the data for a group of Junctions?

Group edits can be made by either creating a domain or by creating a selection.

Using the Domain Manager - Create a domain selecting the specific junctions that you want to edit. Refer to the section on Domain Manager for details on the domain creation process. Once the domain has been created, choose the InfoWater Pro Ribbon in the Edit Group using the → DB Editor icon Image Modified. Depending on the data you want to edit choose the appropriate table type from among the different database tables. Choose Image Modifiedas the Data Scope and click on OK.

Using the User Selection - Select choose the InfoWater Pro Ribbon in the Edit Group using the → DB Editor icon Image Modified.  Depending on the data you want to edit choose the appropriate table type from among the different database tables. Choose as the Data Scope and choose the User Selection Image Modified command. This places the software in User Selection Mode.  In InfoWater Pro, the Selected elements will be in a cyan color.  Once all of the desired junctions are selected, right click and choose Enter to access the DB Tables for the selected junctions.

Once the specific tables have been opened with the desired scope, enter data one cell at a time or Block Edit data to make changes in bulk to multiple cells.

Note

Group Editing for certain specific features may also be done by choosing the Group Editing icon or the Edit Domain icon under the InfoWater Pro Ribbon in the Edit Group . Refer to the sections on Group Editing and Edit Domain to learn more.

Delete a Junction?

To delete a junction, select the Delete Node option Image Modified in the InfoWater Pro Ribbon in the Edit Group → Edit Command dropbox. Select the node to be deleted and InfoWater Pro prompts

...

you to confirm deletion (if the Delete Confirmation checkbox Image Modified is checked in the Operation Settings tab in the Preferences settingsImage Modified.

The active selected junction in the Model Explorer - Attribute Tab window may also be deleted by selecting the Delete icon Image Modified with the InfoWater Pro prompt to confirm element deletion.

Note

All pipes attached to the Junction being deleted will also be deleted if the Auto Pipe Delete checkbox is checked in the Operation Settings tab in the Preferences settings.  The Junction and associated pipes are deleted and saved in the InfoWater Pro recycle bin and can be recalled from the database using the Model Explorer - Command Center Tab under  from the Utilities -> Recall (node or Pipe) command. However, if Auto Database Packing is checked (Operation Settings tab in the Preferences settings), then any element deleted is permanently deleted from the database and cannot be recalled. Deleted elements can be recalled until the Pack and then Clean commands (found in the Model Explorer - Command Center Tab under  from the Utilities → Database menu list) are completed which removes deleted element ID's from the database.

Recall a deleted Junction?

To recall a deleted junction, go to Model Explorer - Command Center Tab

...

, then go to  Utilities ->

...

Recall, and select theNode command. In order to perform the recall,

...

you must know the ID of the junction that was deleted. You may choose the Show Deleted Node command to obtain a list of

...

nodes deleted from the InfoWater project but saved in the InfoWater recycle bin. Deleted elements can be recalled until the Pack and then Clean commands (found in the Model Explorer - Command Center Tab under Utilities → Database menu list) are completed which removes deleted element ID's from the database permanently.