Void Ratio - Defines the percentage of the tank that is available for storage. This is dictated by the type of fill material that is used, i.e. 100% if empty or typically 30% for rubble.

Average Average Slope - The average side slope is determined from the difference in the Top Area and Base area, assuming circular sides.

...

Enter the depth increment for the tank area spreadsheet. Small values lead to a more accurate result but limit the height of the structure.

Sizing Calculator

...


The Sizing Calculator option allows the user to re-size the Tank by specifying a volume and a parameter to modify to achieve that volume.  It also allows the user to specify a Side Slope for the Tank. The Sizing Calculator is discussed in more detail in the Stormwater Control Sizing Calculator.

...

Inlets

Explore the Inlets page for more details on the different types of Inlets that can be specified.

...

Outlets

Explore the Outlets page for more details on the different types of Outlets that can be specified.

...

Advanced

TODO - New Screenshot

Base Infiltration Rate - Defines the rate of infiltration through the base of the filter area. This should be determined from a performance site test.

...

Roughness - Colebrook-White roughness value. Used by the Colebrook-White Formula equation to calculate the velocity and therefore time of travel when using the Colebrook-White option.

...

Pollution