An area can be entered directly or calculated automatically from the polygon drawn on the Plan.
The Area, Volumetric Runoff Coefficient and Time of Concentration values shown in the preliminary Sizing tab will be used for initial sizing of pipes and stormwater controls using Rational Method style calculations.
If these values are not entered here, the default values or the values from the current dynamic sizing runoff method will be used.
Used to factor the runoff when the Time Area Diagram or Time of Concentration Runoff Methods are selected. If a UK Rainfall pattern (FSR / FEH) is selected in the Analysis Criteria, values can instead be specified seasonally. The CVs specified will be used for the Summer and Winter storm analysis, if that type of storm is enabled in the Select Rainfall section within the Analysis Criteria.
A calculator is available which allows the Volumetric Runoff Coefficient to be calculated from Land Use and Overland Slope.
The preferred runoff methods can be selected - select from the methods below for details and required input parameters.
Scroll pdf ignore | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Section Pages
|
Workflow - What's next...?
Inflows connect to either Junctions or Stormwater controls via Inlets. Specify an Outlet on these objects then choose to connect to another Junction or Stormwater Control.