Brings up the options dialog box and provides display (General) options, Symbols options, and Labeling options.
Under the General tab, as shown below, the user can select to automatically run the previous sequences sequence, opt for highlighting junctions with low pressure and clean pipe only, set the sequence time-step delay, and specify the number of decimal places for display.
The last existing sequence will be automatically evaluated (run) before a new sequence can be created. Unsuccessful evaluation will abort the creation process of a new sequence.
Junctions in the defined flush area with a pressure less than the specified Minimum System Pressure will be highlighted when viewing UDF results. For each sequence, up to 10 junctions (in the current flush zone) which have the most pressure deviation from the specified minimum system pressure will be highlighted.
Clean pipes are defined as pipes which are flushed with velocity greater than (or equal to) the desired minimum flush velocity. If checked, InfoWater UDF will highlight (color-code) the clean pipes only. If this option is unchecked, pipes will be highlighted as flushed per the defined on the general tab of the flush sequence manager.
Selecting this item will hide the Sequence Manager Window during the hydrant, pipe and valve selection. Selecting this item will hide the Sequence Manager during the selection process.
This option sets and enforces a maximum scale and prevents the sequence from being zoomed in too far.
Adds an additional minor loss to represent the presence of a Dechlorination device in the in the flushing stream.
Enter the duration in milliseconds of the pause between sequences when using the sequence slide.
Enter the number of decimal places that will be displayed for all numeric fields. This applies to input and output data. Type your drop-down text here.
Check this box to convert the units for the results in output flow to gallons per minute or liter per second.
Check this box to convert the units of flush volume to gallons, for the results.
OK - Click to save any changes and close the dialog box.
Cancel - Click to close the dialog box without saving any changes.
Under the Symbols tab, as shown below, flow arrows can be set. The user can also select the color, line width, and symbol size of the clean and flushing pipes.
Symbols Tab
Select to show the direction of flow in all pipes flushed by a previous sequence will be highlighted when viewing UDF results.
The size of the flow arrows displayed when the Show Flow Arrows option is checked.
Pipes being flushed by the current sequence will be colored as specified here when viewing results.
Pipes being flushed during the current sequence will be the thickness specified here when viewing results.
Pipes already flushed before the current sequence will be colored as specified here when viewing results.
Pipes flushed during a previous sequence will be the thickness specified here when viewing results.
The hydrant used for flushing by the current sequence will be colored as specified here when viewing results.
The hydrant used for flushing the current sequence will be highlighted with a circle of this size.
The valve opened or closed for the current flush sequence will be colored as specified here when viewing results.
Valves that are opened or closed for the current sequence will be highlighted with a circle of this size.
Select highlighting symbol from options in the drop-down menu.
Highlight Closing Valves Using Different Color
Select this checkbox to show the valves closed in the previous sequences with a new desired color.
OK - Click to save any changes and close the dialog box.
Cancel - Click to close the dialog without saving any changes.
Under the Labeling tab, label properties for the hydrant and pipe results can be set.
Labeling Tab
The labeling features allows a mix of labeling between hydrants and valves. By selecting either ID or Output Results allows the data to be mixed between the hydrant, valve, and pipe elements.
If the "Active Sequence" for Hydrants, Valves and Pipes is selected, it will label the active sequence only and not the entire UDF zone.
By un-selecting the active sequence It offers the ability to turn off all UDF labels.
Symbol Options - Opens the Symbol Options dialog box.
OK - Click to save any changes and close the dialog box.
Cancel - Click to close the dialog without saving any changes.