Converts values to be expressed in a new selected unit.

Parameter

Description

Input Data*

Defines the time series data fed into the function. This can be a sensor ID or another function

Unit

Specifies the desired output units.
The units must match the sensor type.

*Input data is optional in most cases. If Info360 detects that the first input is time series data, it will be applied to the function. Otherwise, the current active sensor's data will be used, which is often the case in Reference Charts.

Example Usage as an Expression:

ConvertUnit(Sum(Volume(),24),'MG') - Outputs the cumulative volume through the current sensor over the past 24 hours in units of million gallons (assuming data is hourly).

Note that Volume(Convert('MGD') would not work, because Volume requires complete sensor data rather than a processed function.

Example Reference Chart:

The simple example below shows tank levels in feet being converted to meters using ConvertUnit('m').

 


For information on setting up custom equations and syntax, please refer to Analytical Functions.