The Rainwater Tank option allows flow to be captured with a predefined Harvesting Demand and removed from  Inflows ( Catchment Area Green Roof Roof and/or Input  Hydrograph).


Tick the Use Rainwater Tank option to activate the variables and specify rainwater tank details.

Rainwater Tank: Specifications


Number of Tanks - The Rainwater Tank can represent a single tank or the combined volume of a number of tanks.

The Rainwater Tank is considered as two distinct parts:

  • Retention part which supplies the Harvesting Demand.
  • Detention part which can be used to provide additional storage for stormwater control.

 

Retention Used:

If Retention Used is ticked the volume of the Retention part is used to supply the Harvesting Demand. If un-ticked inflow passes only into the Detention part, any further inflow passes downstream.

Volume - Enter the volume available in the Retention part of the tank. This volume is multiplied by the Number of Tanks value. The volume can be calculated using the  Volume Calculator.

Initial Percentage Used - Enter the percentage of the Retention part of the tank used at the beginning of Analysis.

Initial Volume Used - Shows the volume of the Retention part of the tank used at the beginning of Analysis.

Harvesting Demand - Enter the Harvesting Demand flow rate. This volume is multiplied by the Number of Tanks value.

Detention Used

If Detention Used is ticked the volume of the Detention part is used to to capture the inflow and outflow to pass downstream. If un-ticked inflow passes directly into the Retention part and any further inflow passes downstream.

Volume - Enter the volume available in the Detention part of the tank. This volume is multiplied by the Number of Tanks value. The volume can be calculated using the  Volume Calculator.

Initial Percentage Used - Enter the percentage of the Retention part of the tank used at the beginning of Analysis.

Initial Volume Used - Shows the volume of the Retention part of the tank used at the beginning of Analysis.

Outflow Limit - Enter the maximum Outflow rate possible. This volume is multiplied by the Number of Tanks value.


See Also

Rainwater Tank Analysis


Rainwater Tank

Workflow - What's next...?

Inflows connect to either  Junctions or  Stormwater controls  via  Inlets . Specify an  Rainwater Tank on these objects then choose to connect to another Junction or Stormwater Control.

Previous: Roof  | Next: Volume Calculator